VF(R)-12 Vacuum Circuit Breaker

The VFR-12R mid mounted sealed vacuum load switch fuse combination device (hereinafter referred to as the vacuum switch) is a new generation of vacuum switch equipment developed based on a special design concept and market demand

Product Profile

◆General

VF(R)-12 indoor embedded high-voltage alternating-current vacuum load switch-fuse combination(“vacuum load switch”)is a new-generation vacuum switching equipment developed based on unique design ideas to meet the market demand.It is widely used for indoorarmored air-insulated switch cabinets.In normal conditions,it can operate within its technical parameters in any grid of the specified voltagelevel safely and stably.

◆Product standards

The VF(R)-12 vacuum load switch is produced in line with the following standards and codes.

● GB 3804-2004 High-voltage load alternating-current switches for rated voltage above 3.6 kV and less than 40.5 kV

● GB 16926-2009 High-voltage load alternating-current switch-fuse combinations

◆Operating conditions

Normal operating conditions

● Ambient temperature:-40℃~+40℃(below 35℃ within 24 hours)

● Relative humidity:≤95%(daily average)or≤90%(monthly average)

●Altitude:≤1000m

◆Technical parameters

   ItemUnitReference value
VF-12/T630-20
Vacuum load
switch
VFR-12/T125-50
Vacuum load
switch-fuse
combination
VFH-12/T630-25
High breaking
capacity vacuum
switch
VFHR-12/T125-50
High breaking
capacity vacuum
switch-tuse
combination
   Rated yoltagekV12121212
ightning impulse withstand voltagekV75757575
    Rated insulation level 1min power-frequency withstand voltagekV42424242
   Rated frecuencyHz50/6050/6050/6050/60
   Rated currentA630125(fuse)630125(fuse)
   Rated short-circuit breaking currentkA50(fuse25(are suppreson chamber)25im pcesson harx
   Rated short-circuic making current (peak value)kA5063
   Rated short-time withstand currentkA2025
   Rated withstand current (peak value)kA5063
   Rated breaking current of cable during chargeA16
   Rated breaking current of no-load transformerkVA12501250
   Rated breaking take-over currentA31503150
   Breaking times of the rated short-circuit currentTimes
   Mechanical lifeM2 levelM2 leveM2 leveM2 level
   Weightkg125

◆Transformer capacity and fuse selection

● The fuse can cut off a large short-circuit current in less than 10 ms and its breaking current can be up to 50KA.Thus,it can protect the

transformer most effectively.

● In terms of match between the transformer and the fuse (Table 1),the potential surge current of the fuse must be considered.Thus,fusingcurrent of the fuse must be 1.6 times of the rated value;designer must consider possible fluctuations of other parameters of the grid and reservemargins for them.If a fuse is selected for high-voltage motor protection,designer must consider frequency of start of the high-voltage motorbecause frequent starts of the high-voltage motor will result in the fuse’s failure when timely cooling is not available.

◆Fuse selection

Primary voltage of
the transformer(kV)
Capacity of
the transformer(kVA)
Model of the fuseRated current
of the fuse(A
Model for the domestic marketModel for international market
6.6200XRNT-1012kV BDGHC31.5
25040
300/31550
40012kV BDGHC63
50080
63090

◆Overall and Installation dimension

Overall dimension of VF(R)-12(wheeled)indoor high-voltage alternating-current vacuum circuit breaker

abb vacuum circuit breaker
Cabinet width(mm)P(mm)A(mm)B(mm)C(mm)E(mm)φW(mm)
65015050053049020335
80021065068064027835
100027585088084037835